Withdrawal
Disconnect the ground wire from the battery.
Cut cable tie -A-, press cable to one side.
Detach profiled rubber trim -C- from body.
Remove 4 nuts 3-.
Pull out cover -B-.
Disconnect the upper heater fan shroud from the lower shroud and pull it out.
Disconnect electrical wires -F- from heater blower.
Insert the wire clip -E- into the existing hole and detach by pulling on the clip -D-.
Pull out the heater fan and its lower casing.
Installation
Attention: Do not remove the impellers from the motor and do not rotate them on the axle. The impellers are balanced on the shaft.
Insert the lower heater fan cover.
Insert heater fan.
Attention: The black impeller must be on the right side.
Insert the heater fan mounting clip and snap the wire clip into place.
Connect electrical wires and connector.
Insert the upper heater fan cover and snap into the lower cover.
Connect the ground wire to the battery and check the functioning of the heater fan at all speeds, if necessary, eliminate the malfunction.
Insert cover and secure with 4 nuts.
Fasten the cable to the cover with new clamps.
Insert profiled rubber pad.