Withdrawal
Remove glove box.
Use a narrow screwdriver to press the cable out of the clip -1- on the corresponding choke valve, on the support -2- and pull out the cable.
Remove the air distributor shaft, having previously opened the fixing hook.
Remove the heater control. Do not disconnect connectors.
Disconnect and remove the appropriate cable.
Installation
Connect a new cable in the heater control panel and press the cable with a narrow screwdriver into the choke lever until it clicks into place. Fasten the support. When the handle is turned from stop to stop, the cable is automatically adjusted.
Install the distributor shaft.
Install the heater control panel.
Install glove box.