Withdrawal
Detach control unit -1-. To do this, insert two feeler gauges -2- on the left and right and press out the spring clips -3- in the positions shown.
Attention: The probes must be inserted exactly in the indicated places -3- with some force. If you cannot pull out the control unit in this way, you need to remove the center console and pull out the control unit from the inside.
Pull out the control unit.
Unclip and disconnect multi-pin plugs -1-. To do this, press the hook -2- downwards and move the clip -3- to the side. Due to this, the switch is removed by moving upwards.
Other plug connectors are disconnected by compressing the locking devices.
Installation
Insert and secure plugs.
Attach multi-pin plug -1- and tighten by repositioning retaining clip -3-. Lock retaining clip -3- -2-. Check the tightness of the plug and the retaining clip.
Attach the control unit, evenly press and fix.