Withdrawal
Attention: Do not make open fire! Fire hazard!
Disconnect the positive and ground wires from the battery.
Remove the fuel gauge. The fuel hoses on the bottom of the sensor remain connected.
Squeeze both locking hooks 22 on the mount and pull out the fuel pump 5 together with the fuel supply dispenser 1.
Loosen clamp 18, remove strainer 6 and clean it.
Installation
When installing a new pump, move the mount 21, pressure damper 14 and check valve 11 onto it, as well as all hoses and electrical wires. At the same time, fix the electrical wire with a clamp approximately in the middle of the fuel hose.
Screw on the strainer.
Insert the fuel pump together with the fuel gauge and click into place. Check that the locking hooks are secure.
Install the fuel gauge.
Connect the wires to the battery.