Removal and installation the injection system receiver (M47T2)
1. Remove the intake manifold.
Attention:
- When working with oil, fuel and coolant circuits, the generator must be protected from contamination.
- Cover the generator.
- Failure to comply with this condition may result in generator failure.
Attention:
- Collect and dispose of leaking fuel.
- Observe the applicable national disposal regulations.

2. Disconnect high pressure lines (1-4).
Tightening torque: 23 Nm.
3. Unlock and disconnect the connector from the pressure sensor.
4. Unlock and disconnect the connector from the pressure regulator.

5. Remove the high pressure line (1).
6. Remove the screws.
7. Remove the receiver (2).
8. Installation should be carried out in the reverse order of removal, taking into account the above notes.