Replacing the front pulse sensor
Caution: Observe the ESD protection instructions (ESD - Electrostatic Discharge).

1. Open the connector housing (1), remove the connector (2) from the holder and disconnect it.
2. Remove the cable together with the rubber bushing from the holders on the shock absorber strut and onto the body.
Note: When installing, make sure the connector is securely fastened and the rubber bushings are positioned correctly.

3. Remove the Allen screw (1).
4. Remove the pulse sensor (2) from the hole.
Tightening torque: 8 Nm.
5. Clean the hole for the pulse sensor and lubricate it with Staburags NBU 12/K grease.
6. Installation should be carried out in the reverse order of removal, taking into account the above notes.