To check the signal in the secondary target of the static ignition distribution system, it is necessary to prepare a tool «12.7.030». Remove ignition coil. Attach fixture «12.7.030» (pic. 3.51) to the measured ignition coil and spark plug.
Clamp the terminal for measuring the high voltage current on the high voltage wire. Clamp the earth wire of the adapter with the earth of the vehicle and the earth of the ignition coil. Connect the diagnostic connector (arrow). Fix a static signal on the oscilloscope screen (pic. 3.52), by pressing the key «R».
In the absence of a signal, further troubleshooting is carried out according to the Diagnostic Guide for electrical equipment of the DIS system.