Remove bolts (dark arrows) fasteners, remove the expansion tank of the cooling system (1, fig. 4.133) up (light arrow) and put it aside. The pipes remain connected to the tank.
Note. When removing the oil pressure sensor, a small amount of oil flows out.
Prepare a clean rag to collect the leaking oil and unscrew the oil pressure sensor (arrow, fig. 4.134).
When installing the oil pressure sensor, tighten to 27 Nm (2.7 kgf·m).
Install the oil filter cover (M10) and tighten it to 33 Nm (3.3 kgf·m), check engine oil and coolant levels.
Place the vehicle on a level surface, start the engine and let it idle until the oil pressure indicator goes out.
Switch off the engine, hold for 5-7 minutes and check the oil level in the engine, restore it if necessary.