Rated power - 1.70 kW
Power consumption at idle,
- at U=11.5 V, A
- at armature speed 2900 min-1
Braking torque - 17.5 Nm
- with current consumption 650 - 840 A
- at battery voltage 3.8 V
The minimum voltage of operation of the traction relay is 8.0 V
The minimum height of the brushes is 8.0 mm
Axial armature clearance - 0.05–0.4 mm
Radial runout in bearings - 0.03 mm
Groove depth between collector plates - 0.5–0.8 mm
Note. The traction relay can be checked without removing the starter from the engine in the following order.
Stop the engine, place the gearshift lever in neutral and apply the parking brake. Remove the lower protective casing of the engine compartment and bridge the contacts for a short time «30» (+AB) And «50» (egnition lock). The starter drive gear should go forward sharply, a characteristic click is heard. The traction relay is OK.